AMX CCD-RS

AMX CCD-RS mode d'emploi

(1)
  • Dimmer Switch Remote
    Switch
    Remote
    Dimmer
    Installation Instructions
    Please Read Before Installing
    Multigang Installations
    In multigang installations, several controls are grouped
    horizontally in one multigang wallbox.
    When combining controls in a wallbox, derating is
    required; however, no derating is required for remote
    dimmers / switches.
    Derating Chart
    Control Load Type End of
    Gang
    Middle
    of Gang
    -6D
    Incand. 500 W 400 W
    MLV
    400 W /
    500 VA
    300 W /
    400 VA
    -6NA
    Incand./ ELV 500 W 400 W
    MLV
    400 W /
    500 VA
    300 W /
    400 VA
    -10D,
    -10ND
    Incand. 800 W 650 W
    MLV
    600 W /
    800 VA
    500 W /
    650 VA
    -F6AN-DV*
    3-wire
    Fluorescent/
    LED
    5 A 3.5 A
    50
    ballasts
    35
    ballasts
    -8ANS
    Lighting 6.5 A 5 A
    Motor
    1/4 HP
    5.8 A
    1/6 HP
    4.4 A
    -8S-DV
    Lighting
    8 A
    (2-gang)
    7 A
    (3-gang)
    7 A
    Motor
    1/10 HP
    3 A
    * The maximum load for the -F6AN-DV is either the derated load or
    the number of ballasts, whichever is LESS.
    Note: -8ANS, -RD-277 and -RS-277 controls have fins
    that need to be removed for multigang installations.
    -6D, -6NA, -10D, -10ND, -F6AN-DV, -8S-DV, -RD and
    -RS controls do not have fins that need to be removed
    for multigang installations.
    Troubleshooting Guide
    Lutron Electronics Co., Inc.
    7200 Suter Road | Coopersburg, PA 18036-1299
    P/N 044-312 Rev. A 03 / 2012
    Important Notes
    WARNING – Entrapment Hazard –
    To avoid the risk of entrapment, serious
    injury, or death, these controls must
    not be used to control equipment which is not
    visible from every control location or which
    could create hazardous situations such as
    entrapment if operated accidentally. Examples
    of such equipment which must not be operated
    by these controls include (but are not limited
    to) motorized gates, garage doors, industrial
    doors, microwave ovens, heating pads, etc. It
    is the installer’s responsibility to ensure that the
    equipment being controlled is visible from every
    control location and that only suitable equipment
    is connected to these controls. Failure to do so
    could result in serious injury or death.
    Codes: Install in accordance with all local and
    national electrical codes.
    Grounding: When no “grounding means” exist
    in wallbox, the 2011 National Electrical Code
    ®
    (NEC
    ®) allows a control to be installed as a
    replacement if 1) a nonmetallic, noncombustible
    faceplate is used with nonmetallic attachment
    screws or 2) the circuit is protected by a ground
    fault circuit interrupter (GFCI). When installing
    a control according to these methods, cap or
    remove green wire before screwing control into
    wallbox.
    Neutral Wire: -6NA, -10ND, -8ANS and
    -F6AN-DV require a neutral wire connection
    in the wallbox where the dimmer/switch is to
    be installed. If a neutral wire connection is not
    available in the wallbox, contact a licensed
    electrician for installation.
    Environment: Ambient operating temperature:
    32°F to 104°F (0°C to 40°C), 0% to 90%
    humidity, non-condensing. Indoor use only.
    Spacing: If mounting one control above
    another, leave at least 4
    ½
    in (114 mm) vertical
    space between them.
    Wallplates: Lutron
    ® Claro® and Satin Colors®
    wallplates are recommended for best color
    match and aesthetic appearance. Do not paint
    controls or wallplates.
    Cleaning: To clean, wipe with a clean damp
    cloth. DO NOT use any chemical cleaning
    solutions.
    Wallboxes: Lutron recommends using 3
    ½
    in
    (89 mm) deep wallboxes for easier installation.
    Several controls may be installed in one
    multigang wallbox. See Derating Chart.
    Remote Dimmers / Switches: Use only remote
    dimmers (CCD-RD / CCD-RD-277) and remote
    switches (CCD-RS / CCD-RS-277)
    with dimmers /switches. Up to 9 CCD-RD /
    CCD-RD-277 or CCD-RS /CCD-RS-277 may
    be used with controls. Mechanical 3- or 4-way
    switches will not work.
    RF Device Placement: RF dimmers /switches
    must be located within 30 ft (9 m) of an RF
    Signal Repeater. Remote dimmers / switches
    are not required to be within a specific range
    of a repeater.
    For systems with an RF signal repeater,
    RF dimmers / switches cannot be controlled
    by the system until they are programmed in
    a system.
    English
    Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, and ) are registered trademarks and Clear Connect, Hi-lume 3D, Compact SE, and FASS are trademarks of Lutron Electronics Co., Inc.
    NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
    ©2012 Lutron Electronics Co., Inc.
    Mounting Diagram
    Control
    Mounting
    Screws
    Wallbox
    Control
    Included:
    Wire Connectors (1 or 5)
    Mounting Screws (2)
    Adapter
    Mounting
    Screws
    Wallplate adapter and
    wallplate purchased
    separately.
    Wallplate
    Adapter
    Wallplate
    Technical Assistance:
    U.S.A. / Canada: 1.800.523.9466 | Mexico: +1.888.235.2910
    Brazil: +55 (11) 3257-6745 (M-F 8:30 to 17:30 BRT) | Other Countries: +1.610.282.3800
    24 hours a day, 7 days a week www.lutron.com
    * Typical Power Consumption test conditions:
    Dimmer / Switch: load is off, nightlight mode enabled.
    Remote Dimmer / Switch: load is off.
    WARNING – Shock Hazard –
    To avoid the risk of electric shock
    locate and remove fuse or lock
    circuit breaker in the OFF position before
    proceeding. Wiring with power ON could
    result in serious injury or death.
    1. Turn power OFF at fusebox or circuit
    breaker.
    2. Check the installation for short circuits
    before installing control(s). With power
    OFF, install standard mechanical
    switch(es) between Hot and load.
    Restore power. If lights do not work or
    a breaker trips, check wiring. Correct
    wiring and check again. Install control(s)
    only when short is no longer present.
    Warranty is void if control is turned ON
    with a shorted circuit.
    3. Wire controls according to one of the
    following options:
    a. Terminals: Trim or strip wallbox wires
    to the length indicated by the strip
    gauge on the back of the control.
    Push-In Terminals: Use
    with 14 AWG (1.5 mm
    2
    )
    solid copper wire only.
    Do NOT use stranded or
    twisted wire.
    Insert wires fully. To
    release wire, insert small,
    flat screwdriver into slot
    below push-in terminal.
    Push screwdriver in while
    pulling wire out.
    OR
    Each control
    has inside fins
    removed
    Control at middle
    of gang has all fins
    removed
    Do Not remove outside fins on
    controls at the end of gang
    Single Location Installation
    1
    without Neutral
    -6D, -10D (120V~)
    Wiring Diagram 1
    Brass
    Black
    Blue
    1
    Green
    Ground
    Hot/Live
    Neutral
    Load
    Dimmer
    120 V~
    50/60 Hz
    Load Specifications:
    Control Load Type Min. Load Max. Load
    -6D
    1
    Incand. 50 W 600 W
    MLV
    2
    50 W / VA
    450 W /
    600 VA
    -6NA
    1
    Incand./
    ELV
    2
    5 W 600 W
    MLV
    2
    5 W / VA
    450 W /
    600 VA
    -10D
    1
    Incand. 50 W 1000 W
    MLV
    2
    50 W / VA
    800 W /
    1000 VA
    -10ND
    1
    Incand. 10 W 1000 W
    MLV
    2
    10 W / VA
    800 W /
    1000 VA
    -F6AN-DV
    3, 4, 5
    3-wire
    Fluores-
    cent/ LED
    0.05 A 6 A
    1 ballast 60 ballasts
    -8ANS
    6
    Lighting 10 W / VA 8 A
    Motor 0.08 A
    1/4 HP
    5.8 A
    -8S-DV
    7, 8
    Lighting 40 W / VA 8 A
    Motor 0.4 A
    1/10 HP
    3 A
    -RD
    9
    See Dimmer
    8.3 A
    -RS
    9
    See Switch
    -RD-277
    10
    See Dimmer
    -RS-277
    10
    See Switch
    1 Dimmer Load Type: -6D, -10D and -10ND are designed
    for use with permanently installed incandescent, magnetic
    low-voltage, or tungsten halogen only.
    -6NA is designed for use with permanently installed
    incandescent, electronic low-voltage, magnetic low-voltage,
    or tungsten halogen only.
    Do not install dimmers to control receptacles or motor-
    operated appliances. Do not mix incandescent, halogen,
    MLV, or ELV load types on a dimmer.
    2 Low-Voltage Applications: Use -6D,-10D and -10ND
    with magnetic (core and coil) low-voltage transformers
    only. Not for use with electronic (solid-state) low-voltage
    transformers.
    Use -6NA with dimmable electronic (solid-state) or
    magnetic (core and coil) transformers.
    Operation of a low-voltage circuit with lamps inoperative
    or removed may result in transformer overheating and
    premature failure. Lutron strongly recommends the
    following:
    a. Do not operate low-voltage circuits without operative
    lamps in place.
    b. Replace burned-out lamps as quickly as possible.
    c. Use transformers that incorporate thermal protection or
    fused transformer primary windings to prevent transformer
    failure due to overcurrent.
    3 Fluorescent Dimmer Load Type:
    -F6AN-DV is designed for use with permanently installed
    3-wire 120V~ or 277V~ line voltage control fluorescent
    ballasts or LED drivers. Use only with Hi-lume
    ®, Hi-lume®
    3D, Hi-lume
    ® A-Series, CompactSE
    , Eco-10®, or
    EcoSystem
    ® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). Do
    NOT use with any other ballasts or drivers. Do not install to
    control receptacles or motor-operated appliances.
    4 Power Boosters / Load Interfaces: -6NA, -10ND, -F6AN-
    DV, and -8ANS can be used to control power boosters /
    load interfaces. For a list of compatible power boosters /
    load interfaces see www.lutron.com
    5 Maximum Load: The maximum load for the -F6AN-DV is
    either the derated load or the number of ballasts, whichever
    is LESS.
    6 Switch Load Type -8ANS: -8ANS is designed for use with
    permanently installed 120V~ incandescent, magnetic
    low-voltage, electronic low-voltage, or fluorescent loads
    and with motor loads up to 1/4HP (5.8A).
    7 Switch Load Type -8S-DV: -8S-DV is designed for use
    with permanently installed 120V~ incandescent, magnetic
    low-voltage, electronic low-voltage, fluorescent, or motor
    loads; or 277V~ magnetic low-voltage or fluorescent
    loads.
    8 Shunt Capacitor (included): Some -8S-DV installations
    may require the use of a shunt capacitor. This is especially
    necessary for load types sensitive to leakage current
    (i.e. fluorescent ballasts). If load flickers, install a shunt
    capacitor. For shunt
    capacitor installation see Wiring
    Diagram 4 or 8.
    9 120 V~ Remote Dimmer / Switch: -RD and -RS are
    designed for use with 120V~ dimmers / switches.
    10 277 V~ Remote Dimmer / Switch: -RD-277 and -RS-277
    are designed for use with 277V~ dimmers / switches. Do
    NOT use with motor loads.
    1
    When using controls in single location installations, tighten the blue terminal without any wires attached.
    DO NOT connect the blue terminal to any other wiring or to ground.
    2
    Shunt capacitor must be installed inside the load fixture or in a separate J-box.
    3
    Install only 1 dimmer / switch per circuit. Up to 9 remote dimmers / switches may be connected to a
    dimmer / switch. Total blue terminal wire length may be up to 250 ft (76 m).
    4
    Neutral wire dimmers / switches must be connected on the Load side of a multi-location installation.
    Lamp Replacement
    WARNING – Shock Hazard – For
    any procedure other than routine
    lamp replacement, power must be
    disconnected at the main electrical panel.
    Working with power ON could result in
    serious injury or death.
    For your safety during routine lamp
    replacement, remove power from the
    fixture(s) by moving the FASS
    TM switch into
    the OFF position on the dimmer / switch
    and all remote dimmers / switches.
    Symptom Probable Cause and Action
    Lights don’t turn ON / OFF
    when tapswitch on
    dimmer / switch or remote
    dimmer / switch is pressed
    Power not present
    Circuit breaker OFF or tripped. Perform short circuit check.
    FASS
    is in the OFF position. Move FASS
    to the ON position. Check
    the dimmer / switch and all of the remote dimmers / switches. See Lamp
    Replacement.
    Wiring
    Wires shorted. Make sure the blue terminal is not grounded or shorted to
    any other wires.
    Wiring error. Check wiring to be sure it agrees with installation instructions
    and wiring diagrams.
    For -8S-DV, increase load to meet the appropriate minimum load
    requirement or use shunt capacitor or-8ANS. See Load Specifications.
    Load is less than minimum load requirement
    Make sure the connected load meets the appropriate minimum load
    requirement for that control. See Load Specifications.
    For -8S-DV, increase load to meet the appropriate minimum load
    requirement or use shunt capacitor or -8ANS. See Load Specifications.
    Lamps burned out or not installed
    Replace or install lamps.
    Dioded lamps
    If dioded lamps are being used, replace with non-dioded lamps.
    Load flickers or tapswitch
    does not work even if load
    is greater than 40 W (-8S-
    DV only)
    Leakage current
    • Install a shunt capacitor. See Wiring Diagram 4 or 8.
    Light turns ON and OFF
    continuously or lights turn ON
    when tapswitch is pressed,
    then turn OFF
    Load does not meet the minimum load requirement
    Increase load to meet the appropriate minimum load requirement for that
    control. See Load Specifications.
    Install a shunt capacitor with -8S-DV. See See Wiring Diagram 4 or 8.
    For -8S-DV, increase load to meet the appropriate minimum load
    requirement or use shunt capacitor or -8ANS. See
    Load Specifications.
    Load flickers
    (-8S-DV only)
    Load does not meet the minimum load requirement
    Increase load to meet the appropriate minimum load requirement for that
    control. See Load Specifications.
    Install a shunt capacitor. See Wiring Diagram 4 or 8.
    Lights don’t turn ON/OFF
    from a keypad
    Improper programming
    Program according to the system setup guide.
    Out of RF range
    Reposition to be within 30 ft (9 m) of an RF signal repeater.
    Wiring
    Wires shorted. Make sure the blue terminal is not grounded or shorted to
    any other wires.
    Wiring error. Check wiring to be sure it agrees with installation instructions
    and wiring diagrams.
    Wallplate is warm Solid-state control dissipation
    Solid-state dimmers / switches internally dissipate about 2% of the total
    connected load. It is normal for dimmers /switches to feel warm to the
    touch during operation.
    Single Location Installation
    1
    without Neutral
    -8S-DV with optional shunt capacitor
    2
    (120-277V~)
    Wiring Diagram 4
    Brass
    Black
    Blue
    1
    Green
    Ground
    Hot/Live
    Neutral
    Load
    Switch
    120-277 V~
    50/60 Hz
    Shunt
    Capacitor
    2
    Optional
    Single Location Installation
    1
    with Neutral
    -F6AN-DV (120/277V~)
    Wiring Diagram 3
    Brass
    Black
    Blue
    1
    Green
    Ground
    Hot/Live
    Neutral
    Lutron® Ballast /
    LED Driver
    Lutron® Ballast /
    LED Driver
    Dimmer
    120/277 V~
    50/60 Hz
    Black
    Orange
    White
    Orange
    Silver
    Black
    Orange
    White
    Multi-Location Dimmer Installation
    3
    with Neutral
    4
    -F6AN-DV with -RD or -RD-277
    (120/277V~)
    Wiring Diagram 7
    Dimmer
    Remote DimmerRemote Dimmer
    Note: Dimmer must be installed on the
    load side of the circuit.
    Brass/
    Red
    Brass/
    Red
    Black
    Blue
    Green
    Ground
    Hot/Live
    Neutral
    Lutron® Ballast /
    LED Driver
    120/277 V~
    50/60 Hz
    Black
    Orange
    White
    Black
    Orange
    White
    Lutron® Ballast /
    LED Driver
    Brass
    Black
    Blue
    Green
    Ground
    Orange
    Silver
    Black
    Blue
    Green
    Ground
    Status LEDs (Dimmer only)
    Indicate light level; glows softly
    as night light when load is off
    Tapswitch
    Tap on/off
    Dimming Rocker
    Press to Brighten
    Press to Dim
    FASS
    Front
    Accessible
    Service
    Switch
    Dimmer Operation
    Switch Operation
    Status LED (Switch only)
    Indicates light status; glows softly
    as night light when load is off
    Tapswitch
    Tap on/off
    FASS
    Front
    Accessible
    Service
    Switch
    OR
    -RD-277 or
    -RS-277 only
    OFF ON
    Note: Dimmer must be
    installed on the load side of
    the circuit.
    Multi-Location Installation
    3
    with Neutral
    4
    -6NA and -10ND with RD-RD, and -8ANS with RD-RS (120V~)
    Brass
    Silver
    Black
    Blue
    Green
    Ground
    Load
    Brass
    Black
    Blue
    Green
    Ground
    Remote Dimmer/
    Remote Switch
    120 V~
    50/60 Hz
    Brass
    Black
    Blue
    Green
    Ground
    Hot/Live
    Neutral
    Remote Dimmer/
    Remote Switch
    Dimmer /
    Switch
    Wiring Diagram 6
    Single Location Installation
    1
    with Neutral
    -6NA, -10ND, and -8ANS (120V~)
    Wiring Diagram 2
    120 V~
    50/60 Hz
    Brass
    Silver
    Black
    Blue
    1
    Green
    Ground
    Hot/Live
    Neutral
    Load
    Dimmer/Switch
    Screw Terminals: Use
    with 12 AWG (2.5 mm
    2
    ) or
    14 AWG (1.5 mm
    2
    ) solid
    copper wire only. Do NOT
    use stranded or twisted
    wire.
    Wrap wire around screw
    terminal. Tighten securely
    to 5 in-lb (0.55 N
    m).
    b. Wire Connectors:
    Prepare wires. When making wire
    connections, follow the
    recommended strip lengths
    and combinations for the
    supplied wire connector.
    Note: Wire connectors
    provided are suitable for
    copper wire only.
    Wire Connector:
    Strip insulation 3/8 in (10 mm) for 14 AWG
    (1.5 mm
    2
    ) or 12 AWG (2.5 mm
    2
    ) wire.
    Strip insulation 7/16 in (11 mm) for
    18 AWG (0.75 mm
    2
    ) or 16 AWG
    (1.0 mm
    2
    ) wire.
    Use to join one or two 14
    AWG (1.5
    mm
    2
    )
    or 12AWG
    (2.5 mm
    2
    ) wires with one
    18AWG (0.75mm
    2
    ) or 16AWG
    (1.0mm
    2
    ) wire.
    For single and multi-location installations
    see Wiring Diagrams.
    4. Push all wires back into the wallbox and
    loosely fasten the control to the wallbox
    using the control mounting screws
    provided. Do not pinch the wires.
    5. Attach the Lutron
    ® Claro® or Satin
    Colors
    ® wallplate adapter and wallplate.
    See Mounting Diagram.
    a. Install wallplate adapter onto front of
    control(s).
    b. Tighten control mounting screws until
    wallplate adapter is flush to wall (do
    not over-tighten).
    c. Snap wallplate onto wallplate adapter,
    and verify that control is aligned
    properly.
    d. If controls are misaligned, loosen
    mounting screws appropriately.
    6. Restore power. Verify correct local
    operation. See Dimmer Operation or
    Switch Operation.
    Twist wire
    connector tight.
    Installation
    Warranty: For warranty information, please see the enclosed Warranty, or visit
    www.lutron.com/resiinfo
    Multi-Location Installation
    3
    without Neutral
    -6D, -10D with -RD (120V~)
    Wiring Diagram 5
    Brass
    Black
    Blue
    Green
    Ground
    Load
    Dimmer
    /
    Remote Dimmer
    3
    Brass
    Black
    Blue
    Green
    Ground
    Remote Dimmer
    /
    Dimmer
    3
    Brass
    Black
    Blue
    Green
    Ground
    Hot/Live
    Neutral
    Remote Dimmer
    /
    Dimmer
    3
    120 V~
    50/60 Hz
    Note: Dimmer may be installed in any
    location in the circuit.
    Returning Dimmers / Switches to Factory Settings
    Note: Returning a dimmer / switch to its factory settings will remove it from the system and erase all programming
    from it.
    Step 1 : Triple tap the tapswitch on a control. DO NOT release after the third tap.
    Step 2 : Keep the tapswitch pressed on the third tap (for approximately 3 seconds) until the LEDs on the dimmer
    start to scroll up and down quickly, or the LED on the switch flashes quickly
    Step 3 : Release the tapswitch and immediately triple tap the tapswitch again. The LEDs on the dimmer will scroll
    up and down slowly. The LED on the switch will flash slowly.
    The control has now been returned to factory settings and needs to be reprogrammed into a system.
    Multi-Location Installation
    3
    without Neutral
    -8S-DV with -RS or -RS-277 and optional shunt capacitor
    2
    (120277V~)
    Black
    Blue
    Green
    Ground
    Load
    Switch / Remote
    Switch
    3
    Black
    Blue
    Green
    Ground
    Remote Switch /
    Switch
    3
    Brass/
    Red
    Black
    Blue
    Green
    Ground
    Hot/Live
    Neutral
    Remote Switch /
    Switch
    3
    Note: Switch may be installed in any
    location in the circuit.
    Shunt
    Capacitor
    2
    120–277 V~
    50/60 Hz
    Optional
    Wiring Diagram 8
    Brass/
    Red
    Brass/
    Red
    Dimmer:
    CCD-6D, -6NA, -10D, -10ND
    (120V~ 50 / 60 Hz)
    CCD-F6AN-DV (120/277V~ 50 / 60 Hz)
    Switch: CCD-
    8ANS
    (120V~ 50 / 60 Hz)
    CCD-8S-DV (120-277V~ 50 / 60 Hz)
    Typical Power Consumption*: 0.6 W
    Remote Dimmers:
    CCD-RD (120
    V~
    50 / 60 Hz)
    CCD-RD-277 (277
    V~
    50 / 60 Hz)
    Remote Switches:
    CCD-RS (120
    V~
    50 / 60 Hz)
    CCD-RS-277 (277
    V~
    50 / 60 Hz)
    Typical Power Consumption*: 0W
    Designer-Style
    RF Maestro®
AMX CCD-RS

Besoin d’aide?

Nombre de questions : 0

Vous avez une question sur le CCD-RS de la marque AMX ou avez-vous besoin d’aide? Posez votre question ici. Fournissez une description claire et complète du problème et de votre question. Plus votre problème et votre question sont détaillés, plus il sera facile pour les autres propriétaires du CCD-RS de la marque AMX de répondre correctement à votre question.

Consultez gratuitement le manuel de la marque AMX CCD-RS ici. Ce manuel appartient à la catégorie Gradateurs et a été évalué par 1 personnes avec une moyenne de 9.1. Ce manuel est disponible dans les langues suivantes: Français, Anglais, Espagnol, Portugais. Vous avez une question sur le CCD-RS de la marque AMX ou avez-vous besoin d’aide? Posez votre question ici

Spécifications du CCD-RS de la marque AMX

Généralités
Marque AMX
Modèle CCD-RS
Produit Gradateur
Langue Français, Anglais, Espagnol, Portugais
Type de fichier PDF
représentation / réalisation
Type Variateur et commutateur
Design
Rangement A monter
Type de commande Boutons
Couleur du produit Blanc
Certification UL, CSA , NOM, FCC, IC, COFETEL
Puissance
Tension d'entrée AC 120

ModesdEmploi.fr

Vous cherchez un manuel ? ModesdEmploi.fr vous permet de trouver le manuel que vous recherchez en un rien de temps. Notre base de données contient plus d'un million de manuels en PDF pour plus de 10 000 marques. Chaque jour, nous ajoutons les derniers manuels afin que vous trouviez toujours le produit que vous recherchez. C'est très simple : entrez le nom de la marque et le type de produit dans la barre de recherche pour consulter gratuitement et immédiatement le manuel de votre choix en ligne.

ModesdEmploi.fr

© Copyright 2020 ModesdEmploi.fr. Tous droits réservés.

Nous utilisons des cookies pour vous garantir la meilleure expérience sur notre site. Si vous continuez à utiliser ce dernier, nous considérerons que vous acceptez l'utilisation des cookies.

En savoir plus