    This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit.
    Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
    CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive
    contaminants. (Please see specifications for acceptable temperature and humidity range).
    CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before
    servicing the batteries. There are no user serviceable parts inside except for the battery.
    CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
    CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not
    grounded. If you need to de-energize this equipment, turn off and unplug the unit.
    CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer
    component.
    CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in
    accordance with the National Electric Code, ANSI/NFPA 70.
    DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
    applications. DO NOT use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or
    patient care.
    DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation
    from the aquarium can cause the unit to short out.
    DO NOT LIFT USING FACEPLATE. Two people are required to lift this unit. Lift this unit from sides only.
    INTRODUCTION
    Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed power protection, operation and
    performance during the lifetime of the product.
    UNPACKING
    Inspect the UPS upon receipt. The box should contain the following:
    (a) UPS unit (b) User’s manual (c) Emergency Power Off cable (gray) (d) PowerPanel
    ®
    Business Edition software CD (e) Serial cable (f) USB
    A+B type cable (g) Warranty registration card (h) Function Setup Guide
    OVERVIEW
    The PR2000LCD/PR2200LCD/PR3000LCD UPS provides complete power protection from utility power that isn't always consistent. The
    PR2000LCD/PR2200LCD/PR3000LCD features surge protection against power surges and maintenance free batteries for long lasting battery
    backup during power outages. In addition to ensuring consistent power to your computer system and the
    PR2000LCD/PR2200LCD/PR3000LCD also includes software that will automatically save your open files
    and shutdown your computer system during a utility power loss.
    AUTOMATIC VOLTAGE REGULATOR
    The PR2000LCD/PR2200LCD/PR3000LCD stabilizes inconsistent utility power voltage to nominal levels that
    are safe for equipment. Inconsistent utility power may be damaging to important data files and hardware,
    but with Automatic Voltage Regulation (AVR), damaging voltage levels are corrected to safe levels. AVR
    automatically increases low utility power and decreases high utility power to a consistent and safe
    110/120 volts.
    HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
    1. Ensure that the equipment plugged into the outlets does not exceed the UPS unit’s rated capacity (1920VA/1920W for PR2000LCD,
    2200VA/1980W for PR2200LCD, 3000VA/2700W for PR3000LCD). If the rated capacities of the unit are exceeded, an overload condition
    may occur and cause the UPS unit to shut down or the circuit breaker to trip.
    HARDWARE INSTALLATION GUIDE
    1. Your new UPS may be used immediately upon receipt. However, to ensure the battery’s maximum
    charge capacity, it is recommended that you charge the battery for at least 8 hours. Your UPS is equipped
    with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically
    charge whether the UPS is turned on or off.
    2. Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment.
    The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up.
    3. With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup into the
    battery power supplied outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large
    electrical devices into the “Battery and Surge Protected Outlets”. The power demands of these devices may overload and damage
    the unit.
    4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit
    breaker and does not service equipment with large electrical demands (e.g. air conditioner, copier, etc…). The warranty prohibits the use of
    extension cords, outlet strips, and surge strips.
    5. Press the power switch to turn the unit on. The Power On indicator light will illuminate and the unit will “beep”.
    If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at
    least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
    6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
    7. To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every three
    months to ensure battery life.
    8. Insure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
    9. The LCD module is wall-mountable for extended distance control. Follow the steps below for installation procedure.
    a. Remove the LCD module from the front panel.
    b. Hang the LCD module on the wall.
    c. Replacing the LCD on the UPS - To place the LCD back on the UPS, roll up the LCD cable, return it to the space between the front panel &
    battery cover, and replace the LCD.
    DESCRIPTION
    Front Panel
    1 Power Switch / Power On Indicator
    Used as the master on/off switch for equipment connected to the battery power supplied outlets.
    2 Online Indicator
    This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
    3 On Battery Indicator
    During a severe brownout or blackout, this LED is illuminated and an alarm sounds (two short beeps followed by a pause) to indicate the
    UPS is operating from its internal batteries.
    4 Fault
    This LED is illuminated if there is a problem with the UPS.
    5 Replace Battery Indicator
    This LED is illuminated to remind users to replace the battery.
    6 Status/Tab Button
    For UPS status information, press the button for 1 second. For additional information including
    the use of the button as a Tab, please refer to the Function Setup Guide.
    7 Setup/Enter Button
    Press the Setup button for 1 second to enter setup menu and then select the functions for
    configuration. For more information about the Setup/Enter button, please refer to the Function
    Setup Guide.
    8 Control/Up Button
    Press the Control button for 1 second to enter control menu and then select the functions for
    configuration. This button is also used to scroll up. For more information about the Control/Up
    button, please refer to the Function Setup Guide.
    9 Test/Down Button
    Press the Test switch for 1 second to enter test menu and then select the functions for
    configuration. This button is also used to scroll down. For more information about the Test/Down
    button, please refer to the Function Setup Guide.
    10 Logs/Esc Button
    Press the Logs button for 1 second to view the events or logs that have been recorded.
    This button is also used to exit a menu. For more information about Logs/Esc button,
    please refer to the Function Setup Guide.
    Rear Panel
    1 Battery and Surge Protected Outlets
    The unit has ten battery powered and surge protected outlets for connected equipment to
    ensure temporary uninterrupted operation of your equipment during a power failure.
    (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump
    pump or other large electrical devices into the “Battery and Surge Protected Outlets”.
    The power demands of these devices may overload and damage the unit.)
    2 Serial/USB Ports to PC
    The Serial and USB ports allow connection and communication between the
    computer and the UPS unit. Note: Only one port can be used at a time.
    3 EPO Port
    Use the provided gray EPO cable to connect to a provided EPO contact switch.
    Follow the appropriate circuit diagram to the right to wire the cable to your
    EPO configuration. The EPO remote switch is a switch installed in an outside
    area, connected to the unit via the Emergency Power Off cable. In case of an
    emergency, it can be used to immediately cut-off power from the UPS.
    4 TVSS Ground
    The TVSS GND only used for dielectric voltage-withstand test on production.
    5 SNMP/HTTP Network Slot
    Remove the cover panel to install an optional RMCARD to remotely monitor
    and manage your UPS over a network.
    6 Input Circuit Breaker
    Located on the back of the UPS, the circuit breaker provides overload and
    fault protection.
    7 Output Circuit Breaker
    Located on the back of the UPS, the circuit breaker provides overload and fault protection.
    8 AC Input Power Cord
    Heavy-duty power cord.
    REPLACING THE BATTERY
    Replacement of batteries located in an OPERATOR ACCESS AREA.
    1. When replacing batteries, replace with the same number of the following battery: CyberPower / RB12170X4 for the PR2000LCD,
    PR2200LCD and PR3000LCD. Contact CyberPower Systems about replacement batteries.
    2. CAUTION! Risk of Energy Hazard, 12V, maximum 20 Ampere-hour battery. Before replacing batteries, remove conductive jewelry such
    as chains, wrist watches, and rings. High energy conducted through these materials could cause severe burns.
    3. CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
    4. CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic.
    CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING
    TO LOCAL REGULATIONS.
    BATTERY REPLACEMENT PROCEDURE:
    1. Turn off and unplug all connected equipment.
    2. Turn the UPS off and unplug it from the AC power source.
    3. Remove the front panel of the UPS.
    4. Remove two screws from the battery compartment cover and slide the cover completely off of the unit.
    5. Pull out the battery pack on the outside from the compartment. Disconnect the battery connector from the batteries.
    6. Before removing the battery pack on the inside, unlock the cable tie and pull out the battery wires. Disconnect the battery connector from
    the batteries. Pull out the battery pack on the inside from the compartment.
    7. Install the replacement battery pack on the inside by connecting the wire bundle connector (composed of one red wire and one black wire)
    to the connector from the battery pack. Lock the battery wires back with the cable tie.
    8. Install the replacement batteries on the outside by connecting the wire bundle connector (composed of one red wire and one black wire) to
    the connector from the battery pack. Put the battery pack on the outside back into the compartment.
    9. Re-install the battery compartment cover and tighten the retaining screws.
    10. Put the front panel back on the UPS.
    11. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge.
    Note: The battery pack on the outside has a fuse, while the battery pack on the inside has not.
    REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead-acid batteries
    collect used batteries for recycling, as required by local regulations.
    Status Menu/Switch
    Operation Mode
    Load Power
    Load VA
    Load Amps
    Load Energy
    Estimated Runtime
    Battery Information
    Input
    Output
    Last Self Test
    Date & Time
    NCL Output
    Setup Menu/Switch
    Setup Wizard
    Utility Power
    MIN O/P Voltage
    MAX O/P Voltage
    LCD Auto Sleep
    Cycling Display
    Audible Alarm
    Temporarily Mute
    Sensitivity
    Charge Mode
    Low Battery Warning
    Date & Time
    Battery Change Date
    Firmware Update
    Power Meter Reset
    Back to Default
    Delay Turn On
    Delay Turn Off
    Reboot Duration
    Minimum Restore Capacity
    Uptime on Battery
    Reserve Runtime
    BASIC OPERATION
    INSTALLING YOUR UPS SYSTEM
    IMPORTANT SAFETY WARNINGS
    DEFINITIONS FOR ILLUMINATED LCD INDICATORS
CyberPower PR2200LCD

Besoin d’aide?

Nombre de questions : 0

Vous avez une question sur le PR2200LCD de la marque CyberPower ou avez-vous besoin d’aide? Posez votre question ici. Fournissez une description claire et complète du problème et de votre question. Plus votre problème et votre question sont détaillés, plus il sera facile pour les autres propriétaires du PR2200LCD de la marque CyberPower de répondre correctement à votre question.

Consultez gratuitement le manuel de la marque CyberPower PR2200LCD ici. Ce manuel appartient à la catégorie Alimentations d'énergie non interruptible et a été évalué par 1 personnes avec une moyenne de 6.8. Ce manuel est disponible dans les langues suivantes: Anglais. Vous avez une question sur le PR2200LCD de la marque CyberPower ou avez-vous besoin d’aide? Posez votre question ici

Spécifications du PR2200LCD de la marque CyberPower

Généralités
Marque CyberPower
Modèle PR2200LCD
Produit Alimentation d'énergie non interruptible
EAN 649532606566, 6495326065668, 9780130168894
Langue Anglais
Type de fichier PDF
Caractéristiques
capacité de la puissance de sortie 2200
Puissance de sortie 1980
Tension de voltage à l'entrée (min) 75
Tension de voltage à l'entrée (max) 154
tension de voltage à la sortie (min) 120
Tension de voltage à la sortie (max) 120
Fréquence d'entrée 47/63
Estimation de montée subite d'énergie 1030
Filtre de bruit EMI/RFI
Alarmes sonores
Topologie UPS Line-interactive
Connectivité
Nombre de prises en sortie 10
Types de sortie AC NEMA 5–15R, NEMA 5–20R
Prise mâle NEMA L5-30P
Design
Format Tower
Certifié Energy Star
Couleur du produit Noir
Certification UL1778, cUL CSA C22.2 No. 107.3, FCC DOC B
Voyants
Écran LCD
Batterie
Technologie batterie Sealed Lead Acid (VRLA)
Temps de secours type à demi de charge 26
Temps de secours type au chargement complet 8
Batterie échangeable à chaud
Autres caractéristiques
Type de batterie RB12170
Conditions environnementales
Température d'opération 0 - 40
Taux d'humidité de fonctionnement 0 - 90

ModesdEmploi.fr

Vous cherchez un manuel ? ModesdEmploi.fr vous permet de trouver le manuel que vous recherchez en un rien de temps. Notre base de données contient plus d'un million de manuels en PDF pour plus de 10 000 marques. Chaque jour, nous ajoutons les derniers manuels afin que vous trouviez toujours le produit que vous recherchez. C'est très simple : entrez le nom de la marque et le type de produit dans la barre de recherche pour consulter gratuitement et immédiatement le manuel de votre choix en ligne.

ModesdEmploi.fr

© Copyright 2020 ModesdEmploi.fr. Tous droits réservés.

Nous utilisons des cookies pour vous garantir la meilleure expérience sur notre site. Si vous continuez à utiliser ce dernier, nous considérerons que vous acceptez l'utilisation des cookies.

En savoir plus