    OVERVIEW
    FRONT VIEW (FIG 1)
    1. Remote sensor reception indicator
    2. Clock signal reception indicator
    3. MODE: Change settings / display
    4. LIGHT: Activate backlight for 5 seconds
    5.
    / : Increase / decrease settings; activate /
    deactivate clock reception signal
    6. Outdoor temperature and humidity
    Wireless sensor included does not include humidity.
    To receive outdoor humidity you need a wireless sensor with
    the humidity function.
    7. Indoor temperature and humidity
    8. Time zone
    9. Clock with weekday
    10. MEM: View current, maximum, minimum temperature /
    humidity
    11. Ice alert LED indicator
    BACK VIEW (FIG 2)
    1. °C / °F: Select temperature unit
    2. RESET: Reset unit to default settings
    REMOTE SENSOR (FIG 3)
    1. LED status indicator
    2. Wall mount hole
    3. Battery compartment
    4.
    RESET hole
    5. CHANNEL switch
    GETTING STARTED
    INSERT BATTERIES
    1. Remove the battery compartment.
    2. Insert the batteries, matching the polarities (see FIG 2).
    LOCATION MEANING
    Clock / alarm
    Main unit batteries low
    Outdoor temperature Sensor batteries low
    and humidity area
    REMOTE SENSOR
    The main unit can collect data from up to 3 sensors.
    To set up the sensor:
    1. Open the battery compartment (see FIG 3).
    2. Select a channel then press RESET.
    3. Close the battery door.
    4.
    Place the sensor within 30 m (98 ft) of the main unit
    using the table stand or wall mount.
    TIP Ideal placements for the sensor would be in any
    l
    ocation on the exterior of the home at a height of not more
    than 5 ft and which can shield it from direct sunlight or wet
    conditions for an accurate reading.
    Use alkaline batteries for longer usage and consumer
    grade lithium batteries in temperatures below freezing.
    SENSOR DATA TRANSMISSION
    To search for a sensor:
    Press and hold
    + MODE simultaneously.
    The sensor reception icon in the remote sensor area shows
    the status:
    ICON DESCRIPTION
    Main unit is searching for sensor(s).
    A channel has been found.
    The sensor cannot be found.
    TIP The transmission range may vary depending on many
    factors. You may need to experiment with various locations
    to get the best results.
    CLOCK
    CLOCK RECEPTION
    This product is designed to synchronize its clock automatically
    with WWVB-60 signal, within 3200km (2000 miles) of Fort
    Collins Colorado.
    To enable / disable signal reception:
    Press and hold
    to enable or to disable signal
    reception.
    Reception takes 2-10 minutes. If the signal is weak,
    it can take up to 24 hours to get a valid signal. If signal
    reception is unsuccessful, place your unit next to a window,
    press and hold
    to force another signal search.
    Clock signal reception indicator:
    STRONG SIGNAL WEAK SIGNAL NO SIGNAL
    MANUALLY SET CLOCK
    To set the clock manually, disable the signal reception first.
    1. Press and hold MODE.
    2. Press
    or to change the settings.
    3. Press MODE to confirm.
    4. The settings
    order is: time zone, 12/24 hr format, hour,
    minute, year, calendar mode (day month / month
    day), month, day and language.
    Select the time
    zone: (P) Pacific, (E) Eastern, (C) Central or
    (M) Mountain.
    The language options are English (E), German (D),
    French (F), Italian (I), and Spanish (S).
    To select display mode:
    Press MODE to choose between clock with seconds /
    weekday / calendar.
    TEMPERATURE AND HUMIDITY
    To toggle temperature unit:
    Press °C / °F.
    To auto-scan between sensors:
    Press and
    hold
    + MEM to display each sensor’s data
    for 3 seconds.
    To end press
    .
    To toggle between current, minimum and maximum
    records for the selected sensor:
    Press MEM repeatedly.
    To clear the records:
    Press and hold MEM.
    ICE WARNING
    If the channel 1 sensor falls between 3°C to
    -2 °C (37°F to 28°F), LED indicator will flash, and will stop
    flashing once the temperature is out of this range.
    BACKLIGHT
    Press LIGHT to activate backlight for 5 seconds.
    RESET
    Press RESET to return to the default settings.
    PRECAUTIONS
    Do not subject the unit to excessive force, shock, dust,
    temperature or humidity.
    Do not cover the ventilation holes with any items such as
    newspapers, curtains etc.
    Do not immerse the unit in water. If you spill liquid over
    it, dry it immediately with a soft, lint-free cloth.
    Do not clean the unit with abrasive or corrosive
    materials.
    Do not tamper with the unit’s internal components. This
    invalidates the warranty.
    Only
    use fresh batteries. Do not mix new and old
    batteries.
    Images shown in
    this manual may differ from the actual
    display.
    2
    3
    4
    5
    1
    RMR203HGA_M_EN_R2.indd 1 2007.6.21 9:49:08 AM
    P/N:086L004999-013 REV1
    1/2
    www.OregonScientificStore.com
Oregon Scientific RMR203HGA

Besoin d’aide?

Nombre de questions : 0

Vous avez une question sur le RMR203HGA de la marque Oregon Scientific ou avez-vous besoin d’aide? Posez votre question ici. Fournissez une description claire et complète du problème et de votre question. Plus votre problème et votre question sont détaillés, plus il sera facile pour les autres propriétaires du RMR203HGA de la marque Oregon Scientific de répondre correctement à votre question.

Consultez gratuitement le manuel de la marque Oregon Scientific RMR203HGA ici. Ce manuel appartient à la catégorie Stations météo et a été évalué par 1 personnes avec une moyenne de 5.2. Ce manuel est disponible dans les langues suivantes: Anglais. Vous avez une question sur le RMR203HGA de la marque Oregon Scientific ou avez-vous besoin d’aide? Posez votre question ici

Spécifications du RMR203HGA de la marque Oregon Scientific

Généralités
Marque Oregon Scientific
Modèle RMR203HGA
Produit Station méteo
EAN 163120551491, 734811705549
Langue Anglais
Type de fichier PDF
Caractéristiques
Fonctions de mesure Thermomètre d'intérieur
Mesure affichage de la tendance fonctions thermomètre
Fonction horloge
Fonction Alarme
Station météo des données extremum thermomètre
Prévisions météorologiques -
Mesure du taux d'humidité (extérieure) (H-H) 25 - 95
Gamme de mesure: Température intérieure (T-T) -20 - 60
Gamme de mesure: Température intérieure (T-T) -4 - 140
Couleur du produit Blanc
Écran
Écran integré
Puissance
Type de batterie AA
Tension des piles 1.5
Poids et dimensions
Largeur 96
Profondeur 22
Hauteur 50
Poids 62

Foire aux questions

Ci-dessous, vous trouverez les questions les plus fréquemment posées à propos de Oregon Scientific RMR203HGA.

Votre question n'est pas dans la liste ? Posez votre question ici

ModesdEmploi.fr

Vous cherchez un manuel ? ModesdEmploi.fr vous permet de trouver le manuel que vous recherchez en un rien de temps. Notre base de données contient plus d'un million de manuels en PDF pour plus de 10 000 marques. Chaque jour, nous ajoutons les derniers manuels afin que vous trouviez toujours le produit que vous recherchez. C'est très simple : entrez le nom de la marque et le type de produit dans la barre de recherche pour consulter gratuitement et immédiatement le manuel de votre choix en ligne.

ModesdEmploi.fr

© Copyright 2020 ModesdEmploi.fr. Tous droits réservés.

Nous utilisons des cookies pour vous garantir la meilleure expérience sur notre site. Si vous continuez à utiliser ce dernier, nous considérerons que vous acceptez l'utilisation des cookies.

En savoir plus