Pyle PMA82

Pyle PMA82 mode d'emploi

(1)
  • PMA82 to measure air temperature
    PMA82 Anemometer.The PMA82 Anemometer Congratulations on your purchase of the
    1
    Introduction
    measures air velocity in five units of measure: feet per minute (ft/min), meters per sec
    -ond (m/sec), miles per hour (MPH), kilometers per hour (km/hr), & nautical miles per hour
    (knots)&CFM(ft /min). An internal sensor allows
    or Fahrenheit units.
    This meter is
    service.
    Meter Description
    1. Vane sensor
    2. LCD display
    3. Units/°F/°C key
    4. Max/Min key
    5. Hold key
    Note: Battery compartment is on rear of unit
    MAX MIN
    VEL
    1
    2
    3
    4
    5
    6
    7
    Display
    1. MAX MIN Record mode
    2. Temperature display
    3. Temperature units
    4. Velocity units
    5. MAX or MIN mode
    6. Velocity display
    7. Low battery indicator
    CFM
    provide years of reliable
    shipped fully tested and calibrated
    and withproper
    6. On/Off Key
    3
    PMA82
    INSTRUCTION MANUAL
    UNITS
    MAX
    MIN
    1
    5
    4
    3
    6
    2
    shuts off after 15 minutes to conserve battey energy.
    2
    Operation
    Meter Power
    1. Press the POWER button to turn the meter on. If the display does not switch on, check
    that a fresh 9V battery is installed.
    2. Press the POWER button to turn the meter off.
    3. The meter is equipped with an AUTO POWER OFF feature. The meter automatically
    Measuring Air Velocity and Temperature
    1. Place the sensor in the air stream under test.
    2. Read the Air Velocity and Temperature measurements directly on the LCD.
    3. To calculate Air Volume in CFM (cubic feet per minute) or CMM (cubic meters per
    minute) refer to the ‘Useful Equations and Conversions’ section.
    Selecting the Temperature unit of measure (
    o
    C/
    o
    F)
    Press and hold the UNITS key for 3 seconds to select the temperature unit of measure.
    The meter will beep twice and the display will indicate the currently selected unit of
    measure.
    Selecting the Air Velocity unit of measure
    Press the UNITS key to change the unit of measure for Air Velocity measurements. The
    display will reflect the current selection. A list of measurement units is printed in the
    specifications later in this manual.
    Record and Recall MAX / Min Function
    1. To begin capturing the Maximum (MAX) and Minimum (MIN) air
    velocity and
    temperature readings, press the MAX/MIN key and the ‘RECORD’ icon will appear in
    the display.
    2. Now, use the MAX/MIN key to toggle the view from MIN to MAX to RECORD. The
    ‘MAX’ or ‘MIN’ will appear along with the recalled reading for convenience. In RECORD
    mode, the meter will display the current reading but will continue to capture MAX and
    MIN readings.
    3. To return to normal operation, press and hold the MAX/MIN key for 3 seconds to clear
    and stop MAX/MIN recording. The meter will beep twice and the ‘MAX’/‘MIN’ and
    ‘RECORD’ icons will switch off.
    Area Set for CFM
    -Turn off the meter
    -Press the HOLD key and hold
    -While holding the HOLD key turn on the meter.It will now be in area set mode
    “set area” will display.The area range can be set from 0 to 999.9ft
    -Press the MAX/MIN key to shift the radix point(decimal point).
    -Press the HOLD key to shift between flashing digits
    -Press the UNITS key to change the value of the flashing digit
    -After setting the area for CFM(inputting the square footage of the duct0,the
    operator must turn the meter off,then turn the meter on again.At this point,
    the meter will be set to read CFM for the desired area.
    2
    knots (nautical miles per hour) 1.94 - 48.5 knots 0.1 knots ± (3% + 0.4 knots)
    mph (miles per hour) 2.24 -56.0 mph 0.1 mph ± (3% + 0.4 mph)
    km/h (kilometers per hour) 3.6 - 90.0 km/h 0.1 km/h ± (3% + 0.8 km/hr)
    m/s (meters per second) 1.00 - 25.00 m/s 0.01 m/s ± (3% + 0.20 m/sec)
    ft/min (feet per minute) 196 - 4900 ft/min 1 ft/min ± (3% + 40 ft/min)
    Max. 80% RH
    32 °F to 122 °F (0 °C to 50 °C)
    Dual function 8888 count LCD display
    3
    Maintenance
    Battery Replacement
    When the battery power falls low, the low battery icon
    will appear on the LCD. Replace
    the 9V battery by removing the Phillips screw on the battery compartment door and
    accessing the battery compartment. Ensure that the compartment cover is securely
    fastened when finished.
    Cleaning and Storage
    Wipe the meter and vane with a damp cloth as needed. Do not apply abrasive, solvents, or
    other cleaners to the surface of the meter or vane. Store with the battery removed and
    avoid extreme temperature and humidity.
    Specifications
    Circuit description Custom LSI microprocessor design
    Display
    Measurement units m/s, km/h, ft/min, knots , mph, Temperature:
    o
    C/
    o
    F
    Data hold Freezes reading on the display
    Sensor Structure Air velocity sensor: Conventional twisted vane arm with low-
    friction ball-bearing
    Memory Recall Record and Recall Maximum/Minimum (MAX/MIN) readings
    Auto Power off After 15 minutes with disable feature
    Operating Temperature
    Operating Humidity
    Power Supply 9V battery
    Power Consumption Approx. 8.3mA DC
    Air Velocity Range Specifications
    Measurement Range Resolution Accuracy
    (% of reading)
    Temperature Range Specifications
    ycaruccA noituloseR egnaR
    32
    o
    F to 122
    o
    F (0
    o
    C to 50
    o
    C) 0.1
    o
    F (0.1
    o
    C) ± 4.0
    o
    F (2
    o
    C)
    CFM
    Air Flow Range Specifications
    Unit
    Range Resolution Area
    CFM(cubic feet per minute) 0-999,900ft /min 0.1 0.000-999.9ft
    in Celsius
    use will
Pyle PMA82

Besoin d’aide?

Nombre de questions : 0

Vous avez une question sur le PMA82 de la marque Pyle ou avez-vous besoin d’aide? Posez votre question ici. Fournissez une description claire et complète du problème et de votre question. Plus votre problème et votre question sont détaillés, plus il sera facile pour les autres propriétaires du PMA82 de la marque Pyle de répondre correctement à votre question.

Consultez gratuitement le manuel de la marque Pyle PMA82 ici. Ce manuel appartient à la catégorie Anémomètres et a été évalué par 1 personnes avec une moyenne de 5.7. Ce manuel est disponible dans les langues suivantes: Anglais. Vous avez une question sur le PMA82 de la marque Pyle ou avez-vous besoin d’aide? Posez votre question ici

Spécifications du PMA82 de la marque Pyle

Généralités
Marque Pyle
Modèle PMA82
Produit Anémomètre
EAN 68888737579
Langue Anglais
Type de fichier PDF
Design
Type Sonic
Format Pocket/Hand-held
Couleur du produit Noir
Caractéristiques
gamme mesurant la vitesse du vent -
Précision 3
unité mesurant la vitesse du vent ft/s, km/h, kn, m/s, mph
unité de mesure de température F, °C
Écran
Écran inclus
Écran LCD
Puissance
Source d'alimentation Batterie
Coupure automatique de l'alimentation
Batterie
Tension des piles 9
Nombre de batteries prises en charge 1
Poids et dimensions
Poids 250

ModesdEmploi.fr

Vous cherchez un manuel ? ModesdEmploi.fr vous permet de trouver le manuel que vous recherchez en un rien de temps. Notre base de données contient plus d'un million de manuels en PDF pour plus de 10 000 marques. Chaque jour, nous ajoutons les derniers manuels afin que vous trouviez toujours le produit que vous recherchez. C'est très simple : entrez le nom de la marque et le type de produit dans la barre de recherche pour consulter gratuitement et immédiatement le manuel de votre choix en ligne.